RPB–200: RF Receiver

1530 Old Oakland Road, Suite 100

01825-200 Rev. B

San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected]

Page 2 of 8

Quick Start Guide

RPB–200

2.0

Connections

The connection between the PXL controller and the RPB-200 is made through a 7 conductor, shielded, stranded, AWG
24 wire cable (such as Belden 9537 or a larger gauge).

Before running a cable to the RPB-200 you must drill a 1/4 inch diameter hole in the case of the RPB-200 to
accommodate the cable. After the cable has been connected to the RPB-200, the cable/hole can be sealed with a
silicone/RTV type sealer.

2.1

Connecting to the RPB-200

The cable connects to the terminal strip on the RF receiver board, pins 1 through 8 (excluding pins 3 and 6). The cable
shield is not connected at the RPB-200.

2.2

Connecting to the PXL-250W

For an "A" reader connection, the cable connects to TB5 pins 1 through 7 (excluding pin 2). For a "B" reader
connection, the cable connects to TB6 pins 1 through 7 (excluding pin 2).

RPB–200 Cable Connections Connecting to the PXL–250W at TB5/TB6

Figure 2: RPB–200 Connections Figure 3: PXL–250W Connections

Pin #

Function

Wire Color

Pin #

Function

Wire Color

1

Ground

Black

4

Ground

Black

4

Shield

Silver

2

Power

Red

3

12V Power

Red

3

no connection

2

not used

4

Red LED

Brown

6

Red LED

Brown

5

Green LED

Orange

5

Green LED

Orange

6

Yellow LED

7

Data 1

White

7

Data 1

White

8

Data 0

Green

1

Data 0

Green

Advertising