background image

KERN

FKTF 30K5LM

FKTF 60K10LM

Accuracy class

III

III

Readability (d)

5 g

10 g

Verification value (e)

5 g

10 g

Weighing range (max)

30.000 g

60.000 g

Minimum load (Min)

100 g

200 g

Taring range (subtrac-
tive)

30.000 g

60.000 g

Reproducibility

2,5 g

5 g

Linearity

±2,5 g

±5 g

Adjustment points

10 / 20 / 30 kg

20 / 50 / 60 kg

Recommended adjust-
ing weight M1 (not
supplied)

20 kg + 10 kg

50 kg

Humidity of air

max. 80% rel. (non-condensing)

Stabilization time
(typical)

3 sec.

Allowable ambient tem-
perature

+10 °C ... + 40 °C

Warm-up time

2 h

Housing (B x D x H)
mm

350 x 390 x 120

Vibration filter

yes

Weighing plate stain-
less steel mm

340 x 240

Units

see menu

Weight kg (net)

6,5

Data interface

yes (RS232)

Article regular places

400

Number of operators

40

Battery operation with
6 x 1.5 V, size "C"

yes

4

FKTF-BA-e-1511