Briefly press the, Key; the right digit starts flashing. ƒ press the – KERN & SOHN VHS 2T1 Addendum User Manual

Page 4

Advertising
background image

ƒ Briefly press the

TARE

key; the right digit starts flashing.

ƒ Press

the

PRE-

TARE

,

TOTAL

and

TARE

function keys to enter the medium adjustment

value (e.g. 1250 kg) as described above, press the

TARE

key to confirm all

segments until only the NET display arrow flashes.

ƒ Import the adjustment weight (in this case the 1250 kg above).

ƒ To confirm press the

TARE

key for c. 4 sec. The display reverts to “AF00“. The

display shows again the medium adjustment value; the medium adjustment
load (1250 kg) can now be taken off.

ƒ Press

the

TOTAL

key, the NET + ~ display arrows are flashing, the last

adjustment value can be entered.

ƒ Briefly press the

TARE

key; the right digit starts flashing.

ƒ Press the function keys

PRE-

TARE

,

TOTAL

and

TARE

to enter the last adjustment value

(e.g. 1875 kg) as described above, press the

TARE

key to confirm all segments

until only the NET +

~ display arrows flash.

ƒ Import the adjustment weight (in this case the 1875 kg above).

ƒ To confirm press the

TARE

key for c. 4 sec. The display reverts to “AF00“. Again

the display shows the last adjustment value.

ƒ To exit adjustment mode, press the

TOTAL

key; the scales show e. g. AP 11

(internal value)

ƒ Press

the

TARE

key for c. 4 sec; the system reverts to weighing mode, the

scales show the current weight, the adjustment is complete, the adjustment
load (1875 kg) may now be taken off.

Please note: If you readjust adjusted scales with the help of multi-point adjustment,
you should use the smallest weight first, followed by the medium weight and finally
the greatest weight. Use only 1 adjustment value, then set value 2 and 3 to "0000.0“.