Instruction Manual

FH 10– 500 EXT

FH_10-500-BA-e-1213

3

SET:

-

1 x Press: Upper Limit [HidT / Hi Lt]. To
change press: ▲ or ▼ (see section
High/Low Limit function)

-

1 x Press: Lower Limit [LodT]. To change
press ▲ or ▼ (see section High/Low Limit
function )

-

1 x Press: Minimum limit to save peak
values in the instrument’s memory.
[LE.SET / Lo Pe]. Please see section „Min
Limit Peak Save“. To change press: ▲ or
▼ (Only in „Peak-Mode“ active) (see
section min. limit peak save)

-

1 x Press: Sets the Auto-STOP force value
that stops the movement of a test stand.
Adjustment of the force value. To change
press: ▲ or ▼ (only active in „Battery-
Mode“)


-

1 x Press: Sets the AUTO-OFF force value
that stops the movement of a test stand. To
change press: ▲ or ▼ (Only in „Battery-
Mode“ active)

-

1 x Press: Peak-Freeze-Time [PE.2E /
A.PE / HoldT]: Time period in which a peak
value is being shown in the display in sec.
To change press: ▲ or ▼

-

1 x Press: Data Transfer [rS232] to PC
(PC) or to the printer (Print) or (in version U
5.1) to the test stand (stand)


- PC: Pressing SET once: Saves the Settings
- PRINT: Pressing SET twice: sending data to the printer
- STAND: Pressing SET three times: sending a signal to
the Test Stand to stop its movement (in version U 5.1)

Back Light:

PEAK:

Three functions
-

Track mode (continuous measurement)

-

Peak mode (capture of maximum values)

-

Auto-Peak mode, same as Peak-mode, only
without the „Min limit peak save“ function

MEMORY:

Saves the peak values to calculate the average
value (please see section “Memory mode”


DELETE


Deletes stored peak values (only active in
„Memory mode“)



PRINT:

Sends the stored peak values to a PC or Printer
(please see section „Data Output”)


High / Low Limit Function


LEDs to display OK / NOT OK Tests

Lower than lower limt

Higher than higher limit


This function allows efficient testing of OK / NOT OK
measurements of similar or identical testing objects.
A lower and an upper limit value can be defined. The
instrument compares the individual measuring results with
these limit values and shows the OK or NOT OK result by
green or red light diode and by sound.
To set these limit values, please see the SET Menu in
section „Operating keys“.

Measurement (Track Modus)

Display (1) shows the continuous force in a defined
direction (6)

To zero the display, press:



Peak-Hold Function (Peak Mode)


Please press:

Hi Lt

Lo dT

Lo Pe

P.OFF

HoldT

rS232

StoP