LAARS Stor - Installation, Operation and Maintenance Instructions User Manual

Page 9

Advertising
background image

9

Specifications continued-

Table 2: Water Heater Capacities


MODEL

Tank

Capacity

(Gal)

Coil

Volume

(Gal)

Dry Weight

(Lbs)

Wet Weight

(Lbs)

30-Gal. / Res.

30 2.7 140 404

40-Gal. / Res.

40 2.7 172 500

40-Gal. “R” / Res.

38 2.7 172 486

50-Gal. / Res.

50 2.7 196 610

50-Gal. “R” / Res.

48 2.7 180 576

65-Gal. / Res.

60 2.7 196 704

65-Gal. / Com.

58 5.0 265 768

80-Gal. / Res.

75 2.7 224 861

80-Gal. / Com.

73 5.0 293 920

120-Gal. / Res.

116 2.7 355 1324

120-Gal. / Com.

114 5.0 415 1370

Table 3: Water Heater Ratings




MODEL

First Hour

Rating

(Gal/Hr)

Continuous

Draw Rating

(Gal/Hr)

Standby

Heat Loss

Rating

(°F/Hr)

Minimum Heat

Output Rate of

the Heat Source

(BTU/Hr)

Minimum

Heat Source

Flow Rate

(Gal/Min)

30-Gal. / Res.

255 235 1.2

157,000

13.7

40-Gal. / Res.

260 235 1.1

157,000

13.7

40-Gal. “R” / Res.

260 235 1.1

157,000

13.7

50-Gal. / Res.

265 235 0.9

157,000

13.7

50-Gal. “R” / Res.

265 235 0.9

157,000

13.7

65-Gal. / Res.

275 235 0.8

157,000

13.7

65-Gal. / Com.

405 370 0.8

245,000

14.0

80-Gal. / Res.

295 235 0.6

157,000 13.7

80-Gal. / Com.

415 370 0.6

245,000 14.0

120-Gal. / Res.

315 235 0.4

157,000 13.7

120-Gal. / Com.

445 370 0.4

245,000 14.0


NOTES: These ratings were obtained with a heat source output rate
and flow rate as specified in Table 3 and a 180°F boiler water supply
temperature. Other results will be obtained under different conditions.