3  Operation Directions 

3.1  First Time Use 

Use warm water and mild general purpose cleaner to clean the freezer, rinse with clean water

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

and then dry. 

To set the freezer at -40℃: 

Set temperature at -35ºC and connect to power.

The compressor will start up after 3 minutes,

 

   

 

 

   

 

 

 

 

 

 

   

 

check in 30 minutes, if freezer temperature has obviously dropped, it means the refrigeration

   

 

   

 

 

 

 

   

 

 

 

system is operating normally. Once the unit reaches -35ºC the compressor will stop, at this

   

 

 

 

 

 

 

 

 

 

 

   

 

time you can change the set temperature to -40ºC. 

Unit should be run for at least 12 hours before any products are placed in freezer.  

To save power and keep temperature fluctuations to a minimum, open door sparingly and

 

 

 

 

 

 

     

 

 

 

 

 

close door quickly. 

3.2  Adjusting the Temperature 

      

  

Display the temperature 

 

Examine parameter, Not in the setting status: 

Press“▲” to show the setting temperature, after few seconds display will show current

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature. Press“▼” to show the return difference temperature, after a few seconds display

 

   

 

 

 

 

 

   

 

 

 

will show current temperature. 

How to Set the temperature 

Turn into the setting status: 

At the un-setting status,Press”set” one time,Will turn into the setting status.Now the set

 

 

 

 

 

 

 

 

 

 

 

 

 

indicator light,Show the current temperature. 

Set the temperature

: 

At the setting status,Press “▲”“▼” to adjust the temperature. Press 1times to 1℃. 

Press 'SET" more than 2seconds will come to quick set, Confirm by press "SET". Then show

 

 

 

 

 

 

   

 

 

   

 

 

 

 

"L", Press "SET" again will show low alarm set, same method as High alarm set. Then

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

confirmed by press "SET". And back to current temperature 

Quit the setting status

: 

At the setting status,Press “set” more than 5seconds or no operation within 30 seconds,The

 

 

 

 

 

 

 

   

 

 

 

 

 

system will save the setting temperature ,and back to normal work status. 

When compressor delayed time beyond the setting delayed time,Or sensor temperature higher

 

 

 

 

 

 

 

 

 

 

 

 

than setting temperature + return difference temperature,The replay will start refrigeration 

Sensor failure alarm

: 