Accepted for use in food processing industries (if

applicable)

-

Removes scale, slag, tarnishes, and hard water

deposits

-

Easily rinsed out of system

-

No objectionable or corrosive fumes

CERTIFICATION


Heat exchangers are designed and fabricated in accordance
with ASME Code Sec. VIII, Div.1 for symbols “U” and
“UM”. Heat exchangers are CSA approved and have
obtained CRN in Canadian provinces.
Copies of above certificates are available upon request.

1.

GENERAL OPERATION OF
RELIEF VALVE


PRESSURE RELIEF VALVE IS NATIONAL

BOARD CERTIFIED. TEMPERATURE
STEAM RATED

ANS Z21.22 RELIEF VALVES CONFORMS

TO H.U.D./F.H.A. REQUIREMENTS.


Discharge from relief valve shall be conducted to a
suitable place for disposal when relief occurs by
installation of a drain line to any open drain. Make sure
water in drain cannot freeze and cause a stop-up. Relief
line must be such that relief valve outlet and drain line will
drain dry.
Do not use reduced couplings or restrictions to install drain
line to valve discharge.
This valve protects a water system from over-pressure. It
will automatically shut off after providing such protection.
If valve fails to shut off, check for excessive pressure
and/or heat input control operation.






REPLACEMENT PARTS

A. RECIRCULATION PUMP

(ref Figure 6)

Pump replacement parts are :

Impeller

Impeller seal

Body Gasket

Do not attempt to replace motor bearings, replace the
motor as a whole unit. Refer to manufactures specific IOM
for further details.

D.

BLEND VALVE


Service Parts For Model BO
Ref
No

Part No

Description

3

9585L001

Seat, Bolted-In

4

1182

Sleeve

5

11132L050

Capscrews

6

11133

Lockwasher

7

1183

Element O-Ring, Buna-N

8

1096X(TEMP) Element Assembly

9

761

O-Ring

Blend Valve temperature ranges are:

150 degrees F for the first valve
130S degrees F (S = Special 120 degree F unit)

Service Kit No. 9167X(Temp.) Standard Element
Ref
No

Qty Description

Part No.

3

1

Element

1125X(Temp.)

4

1

O-Ring

1205

5

1

O-Ring

277L145

6

1

O-Ring

11080L001

7

1

O-Ring

11079L001


No adjustments are ever required on thermostatic valves.
Once installed a thermostatic valve will provide years of
trouble-free service. It is entirely self-contained, and there
are no external bulbs or lines to become damaged or
broken. There are no packing glands to tighten and no
parts to oil. Temperature is permanently set at factory and
requires no further adjustment.

Operating temperature can be changed only by changing
temperature

element

assemblies

which

is

easily

accomplished by unbolting housing. Element assemblies
are all interchangeable within each lettered valve series.

Larger valves in “B” and “H” series contain multiple
element assemblies in one housing. This means that a
temperature element assembly will fit any size
thermostatic valve housing in that series.