Manual Override for Bi-Rotational Power Units

1. Remove protective label (Fig. 9A).
2. Manually open jack valves with a 5/32" hex wrench (Fig. 7).
3. Using a 1/4" hex bit, insert into auxiliary drive device, i.e. cordless drill or power drill.
4. Insert hex bit into coupler found under protective label (Fig. 10).

5. Run drill forward or clockwise to extend jacks and in reverse or counterclockwise to retract jacks.
6. Close the manual override on the valves that were manually opened (Fig. 8).

Fig. 7 - Bi-Rotational

Fig. 8 - Bi-Rotational

Clockwise for manual override

Counter-clockwise for normal

operation

A

Forward or clockwise to extend; reverse or

counterclockwise to retract.