Troubleshooting Chart - HLG

Problem

Probable Cause

Corrective Action

Jacks will not extend to ground,

pump is running.

Little or no fluid in reservoir

Fill reservoir with DEXRON III

Leg valve is inoperative

Clean, repair or replace

Electronic signal is lost between

switch

Trace wires for voltage drop or loss

of signal and leg valves. Repair or

replace necessary wires or replace

switch.

Any one or two jacks will not retract.

Hose damaged or disconnected.

Replace with new hose or reconnect

hose.

Return valve inoperative.

Replace inoperative return valve.

Electronic signal is lost between

switch and solenoid.

Attempt to retract jacks in MANUAL

mode. If successful, replace control

pad. If not, test for voltage drop

between switch and leg valve.

Repair bad wiring or replace

defective board or valve.

Troubleshooting – Power Unit

Before attempting to troubleshoot the Power Unit, make sure an adequate power source is available. The unit

batteries should be fully charged or the unit should be plugged into to A/C service with batteries installed. Do not

attempt to troubleshoot the Power Unit without assuring a full 12VDC charge.

The following tests require only a DC voltmeter (or DC test light) and a jumper lead.
1. Attach voltmeter (or test light) leads to the negative and positive terminals on motor solenoid. Does

the meter indicate 12VDC? If YES, see Step 2; if NO see Step 3.

2. If YES, at the motor, activate system, check the incoming leads to 12VDC (if necessary, disconnect leads

at wire splices). Does meter indicate 12VDC? If YES, Power Unit needs to be replaced. The motor is

not field serviceable. DO NOT ATTEMPT TO REPAIR. If NO, Inspect all wires and connections between

the motor solenoid and the motor. Repair connections or replace motor solenoid as necessary.

Recheck as in Step 1.

3. If NO, Inspect all connections between battery and motor solenoid. Inspect Manual-reset Circuit

Breaker in battery feed line. Recheck as above in Step 1.

Since there are no field serviceable parts in the motor of the Power Unit, electrical troubleshooting and service is

limited to replacing only those components as previously outlined.
Thorough inspection of wiring and connections is the only other electrical service that can be performed.