Problem

Probable Cause

Corrective Action

System will not turn on and on/off

indicator light does not illuminate.

Coach ignition not in RUN position

Turn ignition to RUN position

Parking brake not set

Set parking brake

Controls have been on for more

than four minutes and have timed

out

Turn ignition OFF and then back ON

Control pad turns on but turns off

when leg button is pushed.

Low voltage on battery

Start coach to charge battery

Control pad turns on, coach will not

auto-level, "jacks down" light is on,

jacks are retracted.

Low fluid level

Check fluid level in reservoir. If fluid

is low, add fluid to FILL TO HERE line

on reservoir. If JACKS DOWN light

remains on call Lippert Service.

Jacks will not extend to ground,

pump is running

Little to no fluid in reservoir

Fill reservoir with DEXRON III ATF

Leg valve is inoperative

Clean, repair or replace

Electronic signal is lost between

control leg valves

Trace wires for voltage drop or loss

of signal. Repair or replace necessary

wires or replace control pad.

Any one or two jacks will not retract.

Hose damaged or unconnected.

Replace with new hose or reconnect

hose.

Return valve inoperative.

Replace inoperative return valve.

Electronic signal is lost between

control and solenoid.

Attempt to retract jacks in MANUAL

mode. If successful, replace control

pad. If not, test for voltage drop

between control pad and leg

valve. Repair bad wiring or replace

defective board or valve.

"Jacks down" light does not go out

when all jacks are retracted.

Low fluid level.

Fill reservoir to proper level with

ATF.

Retract pressure switch inoperable.

Check connection or replace.

Alarm sounds and "jacks down" light

starts flashing while traveling jacks

are fully retracted.

Low fluid level.

Fill reservoir to proper level with

ATF.

Retract pressure switch inoperable.

Check connection or replace.

Jack bleeds down after being

extended.

Valve Manual Override open.

Close override.