High-Speed Microcontroller User’s Guide: DS80C390 Supplement

92 of 158

Table 5-1. SYSTEM CLOCK CONFIGURATION

CD1 CD0

2X

4X/

NAME CLOCKS/MC

MAX EXTERNAL

FREQUENCY (MHz)

0

0

0

Frequency Multiplier (2X)

2

20

0

0

1

Frequency Multiplier (4X)

1

10

0 1 N/A

Reserved

1 0 N/A

Divide-by-4

(Default)

4

40

1

1

N/A

Power Management Mode

1024

40


The system clock and machine cycle rate changes one machine cycle after the instruction changing the
control bits. Note that the change will affect all aspects of system operation, including timers and baud
rates. The use of the switchback feature, described later, can eliminate many of the issues associated with
the Power Management Mode’s effect on peripherals such as the serial port. Table 5-2 illustrates the
effect of the clock modes on the operation of the timers.

Table 5-2. EFFECT OF CLOCK MODES ON TIMER OPERATION

OSC. CYCLES

PER TIMER

0/1/2 CLOCK

OSC. CYCLES

PER TIMER 2

CLOCK, BAUD

RATE GEN.

OSC. CYCLES

PER SERIAL

PORT CLOCK

MODE 0

OSC. CYCLES

PER SERIAL

PORT CLOCK

MODE 2

CD1 CD0

2X

4X/

OSC. CYCLES

PER MACHINE

CYCLE

TxM=1 TxM=0 T2M=1 T2M=0 SM2=0 SM2=1 SMOD=0 SMOD=1

0

0

0

2

2 12 2 2 6 2 64 32

0

0

1

1

1 12 2 2 3 1 64 32

0

1

N/A

Reserved

1 0

N/A

4

4 12 2 2 12 4 64 32

1 1 N/A

1024

1024 3072 512 512 3072 1024 16,384 8192

CHANGING THE SYSTEM CLOCK/MACHINE CYCLE CLOCK FREQUENCY

The microcontroller incorporates a special locking sequence to ensure “glitch-free” switching of the
internal clock signals. All changes to the CD1, CD0 bits must pass through the 10 (divide-by-4) state.
For example, to change from 00 (frequency multiplier) to 11 (PMM), the software must change the bits in
the following sequence: 00

⇒ 10 ⇒ 11. Attempts to switch between invalid states will fail, leaving the

CD1, CD0 bits unchanged.

The following sequence must be followed when switching to the frequency multiplier as the internal time
source. This sequence can only be performed when the device is in divide-by-four operation. The steps
must be followed in this order, although it is possible to have other instructions between them. Any
deviation from this order will cause the CD1, CD0 bits to remain unchanged. Switching from frequency
multiplier to non-multiplier mode requires no steps other than the changing of the CD1, CD0 bits.

1. Ensure that the CD1, CD0 bits are set to 10, and the RGMD (EXIF.2) bit = 0.
2. Clear the CTM (Crystal Multiplier Enable) bit.
3. Set the

2X

4X/

bit to the appropriate state.

4. Set the CTM (Crystal Multiplier Enable) bit.
5. Poll the CKRDY bit (EXIF.3), waiting until it is set to 1. This will take approximately 65536 cycles

of the external crystal or clock source.

6. Set CD1, CD0 to 00. The frequency multiplier will be engaged on the machine cycle following the

write to these bits.