2.5 Hook Switch and Pulse Dial Related APIs

2.5.1 M1x66_HookSwitch

Description

Perform on/off-hook on the FXO channel.

Prototype

M1x66_RET M1x66_HookSwitch (

M1x66_HANDLE channel,
M1x66_HOOK_SWITCH hookSwitch );


Parameters

Data Type

Name

Description

M1x66_HANDLE

channel

Channel handle from FXO open channel.

M1x66_HOOK_SWITCH hookSwitch

Type of hook switch requested.


Return Values

Data Type

Description

M1x66_RET

M1x66_SUCCESS – Successfully performed hook switch.
M1x66_FAILED – Failure.


2.5.2 M1x66_PulseDial

Description

Perform pulse dialing on the FXO channel. This API will bring the FXO channel off-hook then perform
pulse dialing with the digit string provided. Once the dialing is completed the FXO channel will remain
off-hook indefinitely, or until it is manually brought back on-hook.

Up to 30 numeric digits is supported. Valid numeric digit is from ASCII 0 to 9 (i.e., 0x30 to 0x39).

Prototype

M1x66_RET M1x66_PulseDial (

M1x66_HANDLE channel,
char *dialSting );


Parameters

Data Type

Name

Description

M1x66_HANDLE

channel

Channel handle from FXO open channel.

char

*dialString

Numeric dial string of up to 30 characters max.


Return Values

Data Type

Description

M1x66_RET

M1x66_SUCCESS – Successfully dialed.
M1x66_FAILED – Failure.