2 API Descriptions

This section contains the detail description of each API. Table 1 provides a summary of the APIs.

Table 1: API Overview

IOCTL Name

Description

FXO API Initialization and Termination

M1x66_FxoApiInit

API subsystem initialization.

M1x66_FxoApiRelease

API subsystem release or termination.

Device/Channel Open, Close and

Initialization APIs

M1x66_OpenDevice

Open FXO device of event reporting.

M1x66_CloseDevice

Close an opened device.

M1x66_OpenChannel

Open FXO channel for operation.

M1x66_CloseChannel

Close an opened channel.

M1x66_InitChannel

Initialize channel for specific region.

M1x66_PCMIfConfig

Configure PCM interface parameter.

M1x66_PcmConfig

Configure PCM timeslots and codec.

M1x66_PcmActivation

Activate PCM channel.

M1x66_PcmDeActivation

De-activate PCM channel.

M1x66_HookSwitch

Perform hook switching – on/off-hook.

Hook Switch and Pulse Dial Related APIs

2.1.1 M1x66_HookSwitch

Description

Perform on/off-hook on the FXO channel.

Prototype

M1x66_RET M1x66_HookSwitch (

M1x66_HANDLE channel,
M1x66_HOOK_SWITCH hookSwitch );


Parameters

Data Type

Name

Description

M1x66_HANDLE

channel

Channel
handle from
FXO open
channel.

M1x66_HOOK_SWITCH hookSwitch

Type of
hook switch
requested.


Return Values

Data Type

Description

M1x66_RET

M1x66_SUCCESS – Successfully
performed hook switch.

Pulse dialing.