2.13.3 M1x66_StopMeasureCurrent

Description

Stop the line current measurement.

Prototype

int M1x66_StopMeasureCurrent (

M1x66_HANDLE channel,
unsigned int sampleTime,
unsigned int averageSampleCount );


Parameters

Data Type

Name

Description

M1x66_HANDLE

Channel

Channel handle obtained from FXO open channel.

unsigned int

sampleTime

Time interval between two consecutive samples.

unsigned int

averageSampleCount

Sample count for average calculation.


Return Values

Data Type

Description

M1x66_RET

M1x66_SUCCESS – Successfully stopped.
M1x66_FAILED – Failure.

2.13.4 M1x66_StopMeasureVoltage

Description

Stop the line voltage measurement.

Prototype

int M1x66_StopMeasureVoltage (

M1x66_HANDLE channel,
unsigned int sampleTime,
unsigned int averageSampleCount );


Parameters

Data Type

Name

Description

M1x66_HANDLE

Channel

Channel handle obtained from FXO open channel.

unsigned int

sampleTime

Time interval between two consecutive samples.

unsigned int

averageSampleCount

Sample count for average calculation.


Return Values

Data Type

Description

M1x66_RET

M1x66_SUCCESS – Successfully stopped.
M1x66_FAILED – Failure.