10> FREQUENTLY QUESTIONS SOLVING

Disconnect

Panel button

operation error

No Sound output

Overload indicator

is flashing often

Sound default

Noise

Check the power cord is connected well or not? And the power button on the

front panel is turn on or not?

10.1 Audio relevant question

Check whether the setting of input signal and plus is limited. And will get

more plus from output. So do not try to adjust much the plus of the

equipment and filter. That will caused the output noise being strong.

Check the crossover setting if want output full range signal.

Whether the input signal is over strong? (The max input signal is over

20dBu or not?). Whether the plus of Input/output increased much?

Check the plus of parameter increased much.

Check the input/output is silent or not? The plus of input/output is weak

or not? Check the selection sound source of each output channel. And

confirm whether have signal to relevant input channel. If finished setting the

crossover, confirm the closed frequency of high filter is lower than the

closed frequency of low filter.

Check the lock button on the panel is flashing or not. And unit is locked

status or not.

10.2 RS-232/RS-485 connecting problem

1). Check all the connecting wires, and make sure these are standard wires. Please check the back plate

connecting terminal definition for the reference of connecting standard.

2). While many machines are connected with the head line(485), Please check the address pins of the machines,

and make sure no conflict.

3). Check the USB port, Keep the hardware and software are in the same port.

10.3 BGM switch problem

1). Make sure BGM switch controlling terminal is connected well.

2). Make sure BGM switch controlling signal(difference between two lines) are between +5VDC--+48VDC.