Fitting the hob – CDA CERAMIC HOBS HVC65 User Manual

Page 14

Advertising
background image

13

Fitting the Hob

Unpacking

the

hob:

Take care not to lose or mishandle any parts.

Fitting position of the hob:
This appliance must be installed a minimum of 50mm from any back wall and a minimum of 190mm away from any

adjacent vertical surfaces, e.g. a tall cupboard end panel. This may be reduced to 100mm if the adjacent surface is resistant
to fire (tiles or steel, for example). These dimensions are shown in Fig.12.

If fitting a cooker hood above the hob:
If a cooker hood is to be installed above the hob, the height of the hood above the hob must be at least 600mm (650mm is
recommended) (Fig.13). If the instructions supplied with the hood dictate that the hood must be installed at a height greater
than 600mm, then that height is the minimum required.

Wall furniture requirements:
The minimum height of any cabinet immediately above the hob is 900mm. The minimum height of any adjacent units
(including light pelmets) is 400mm, unless they are manufactured from a material resistant to fire (steel, for example)

Notes:

Do not position this appliance above a refrigeration unit. The heat generated may cause the refrigeration unit to fail.

This appliance is designed to be installed into cabinet units capable of withstanding temperatures of 65°C or greater

above ambient temperature.

If there is no oven to be built in below the hob, an isolation shelf should be fitted to protect the user from high

temperatures. If the hob is to be installed above a working drawer, then a partition should be fitted to protect the

contents and user from the heat generated during use. This should be fitted 100mm below the hob.

Never place perishable foods in the cupboard below the appliance.

Advertising