Series compact control system crestron mc2e – Crestron electronic Crestron MC2E User Manual

Page 10

Advertising
background image

2-Series Compact Control System

Crestron MC2E

Connectors, Controls & Indicators (Continued)

#

CONNECTORS

1

,

CONTROLS & INDICATORS

DESCRIPTION

6

INFRARED-SERIAL

OUTPUT (A – D)

3, 4

A B C D

S G S G S G S G

IR SERIAL OUT

(4) 2-pin 3.5 mm detachable terminal blocks IR/Serial output ports;
IR output up to 1.2 MHz;
1-way serial TTL/RS-232 (0-5 Volts) up to 115.2k baud;
Individual signal generator per port, allowing simultaneous firing of
all ports.

7

IR IN

IR IN

T R S

(1) 3-pin 3.5 mm detachable terminal block;
For connection of the CNXRMIRD IR Receiver (sold separately);
Allows IR wireless control from Crestron or third-party universal
remotes using RC-5 IR commands.

8

I/O (1 – 4)

5, 6

I/O

1 2 3 4 G

(1) 5-pin 3.5 mm detachable terminal block comprising (4) digital
input/output or analog input ports (referenced to GND);
Digital Input: Rated for 0-24 Volts DC, input impedance 20 kΩ, logic
threshold 1.24 Volts DC;
Digital Output; 250 mA sync from maximum 24 Volts DC, catch
diodes for use with “real world” loads;
Analog Input: Rated for 0-10 Volts DC, protected to 24 Volts DC
maximum, input impedance 20 kΩ;
Programmable 5 Volts, 2 kΩ pull-up resistor per pin.

9

RELAY OUTPUT

(1 – 4)

1 2 3 4

RELAY OUT

(1) 8-pin 3.5 mm detachable terminal block comprising (4) normally
open, isolated relays;
Rated 1 Amp, 30 Volts AC/DC,
MOV arc suppression across contacts.

10

COM (A – B)

7, 8, 9

COM B

COM A

(2) DB9 male, bidirectional RS-232/422/485 ports;
Up to 115.2k baud;
Hardware and software handshaking support;
All ports support C2N-NPA8 Network Poll Accelerator

10

.

PIN DIRECTION

DESCRIPTION

1*

To MC2E

(RXD-) RS-422 Receive Data (Idles low)

2

To MC2E

(RXD) RS-232 Received Data

3

From MC2E

(TXD) RS-232 Transmitted Data

4

From MC2E

(TXD+) RS-422 Transmit Data (Idles high)

5

Common

RS-232 and RS-422 Signal Common

6

To MC2E

(RXD+) RS-422 Receive Data (Idles high)

7

From MC2E

(RTS) RS-232 Request to Send

8

To MC2E

(CTS) RS-232 Clear to Send

9

From MC2E

(TXD-) RS-422 Transmit Data (Idles low)

* RS-422 transmit and receive are balanced signals requiring two lines plus
a ground in each direction. RXD+ and TXD+ should idle high (going low at
start of data transmission). RXD- and TXD- should idle low (going high at
start of data transmission). If necessary, RXD+/RXD- and TXD+/TXD- may
be swapped to maintain correct signal levels.