Connectors, Controls & Indicators (Continued)

#

CONNECTORS

1

,

CONTROLS & INDICATORS

DESCRIPTION

11

COMPUTER

COMPUTER

Pin 1

Pin 9

(1) DB9 female, RS-232 computer console port.
Connector is used when programming with a PC. The port is
modem compatible (modem and PC cables not included).
Supports baud rate of up to 115 kB. Use with standard DB9 straight
through cable. Pins 1, 4, 6 and 9 are not connected.

PIN #

ABBREVIATION

DESCRIPTION

2 TXD

Transmit

Data

3

RXD

Receive Data

5 SG

Signal

Ground

7

CTS

Clear To Send

8

RTS

Request To Send

12

LAN

GREEN

LED

YELLOW

LED

PIN 8

PIN 1

(1) 8-wire RJ-45 with 2 LED indicators;
10/100BaseT Ethernet port;
Green LED indicates link status
Yellow LED indicates Ethernet activity.

TYPE

PIN

SIGNALS

1

TD+

2

TD-

3

RD+

4

Connected to pin 5

5

Connected to pin 4

6

RD-

7

Connected to pin 8

8-Position
RJ-45

8

Connected to pin 7

13

NET

11, 12

Four-position terminal block connector for data and power.
Connects to Cresnet control network.

Pin 1 (24) Power

Pin 2 (Y)

Data

Pin 3 (Z)

Data

Pin 4 (G)

Ground

Expandable via C2N-NPA8 Network Poll Accelerator

10

.

14

24 VDC

11, 12, 13

(1) 2.1 mm barrel DC power jack, 24 Volt DC power input;
(PW-2410RU power supply included);
Passes through to NET port to power Cresnet devices.

24VDC

1.0A

1. Interface connectors for IR-SERIAL OUT, IR IN, I/O, RELAY OUT and NET ports are provided with the unit.
2. This LED was labeled ERR on units manufactured prior to 2005. It is functionally the same; only the labeling has changed.
3. Transmission levels on the infrared–serial output connectors are in the 0 to +5 VDC range, which may not be compatible with all RS-232 devices.
4. A port can be used for either IR or RS-232 communications but not both.
5. Digital outputs are TTL values and may not work with devices requiring a “dry” contact closure (e.g. low voltage motor controllers).
6. Ports can be used for either input or output but not both.
7. The pinout of each 9-pin port is non-standard; it contains RS-422 pins in addition to RS-232. This may result in a conflict with some equipment

and therefore all nine pins should not be used. Only the required pins for each communication type should be connected. For RS-232 and –422,
pins 2, 3, 5, 7 and 8 are wired straight through.

8. Data Set Ready (DSR) and Data Terminal Ready (DTR) are not supported.