Inteli•touch – Casablanca Fan Company Victorian Ceiling Fan 63XXT User Manual

Page 7

Advertising
background image

7

R

R

The wall control installs in the same manner as an ordinary light switch, using an existing junction box and wiring. This

controller is designed to signal the fan microcomputer as well as perform normal switching operations. For this reason the

following precautions must be observed:

1. Use

only the Casablanca W-32 wall control.

2. Do not use any additional control with your Inteli-Touch

fan (for example, dimmer, fan speed control, etc.).

3. Do not use more than

one fan per wall control.

4. No other light fixtures or electrical appliances may be

connected on the circuit controlled by the W-32 wall

control.

W-32 is used to describe either white (-11) or ivory finish.
1. Remove the screws and switch plate from the existing switch box.

2. Remove the screws holding the switch in the switch box.

3. Pull the existing switch from the switch box to expose the wire con-

nections.

4. Remove the two wires from the switch.

5. Connect the two wires just removed from the switch to the W-32

wall control black wire and black/white stripe wire. Secure these

connections with wire nuts.

6. Connect the green ground wire coming from the back of the W-32

control to the ground wire in the switch box. Secure the splice with

a wire nut.

7. Install the W-32 in the wall box with the two long screws pro-

vided.

8. Install the wall plate with the two color matched screws.

To control the fan and lights from two locations (a three-way

circuit), use 2 W-32 wall controls.

1. Remove the screws and switch plate from the existing

switch box and the screws holding the switch in the

switch box.

2. Pull the existing switch from the switch box to expose

the wire connections.

3. Determine which wire is connected to the common ter-

minal of the 3-way switch. (The terminal will be marked

on switch).

4. Remove the wire from the common terminal of the 3-way

switch. Connect this wire to the remaining black/white

striped wire on the W-32 control. Secure this splice with

a wire nut.

5. Remove the two remaining wires from the 3-way switch.

Connect one of these wires to a black wire on the W-32

control. Secure the splice with a wire nut. The remaining

wire is to be connected to the other black wire on the

W-32. Secure the splice with a wire nut.

6. Connect the green ground wire coming from the back of

the W-32 control to the ground wire in the switch box.

Secure the splice with a wire nut.

7. Install the W-32 in the wall box with the two long screws

provided.

8. Install the wall plate with the two short color-matched

screws provided.

9. Installation of the second W-32 control is identical.

Repeat steps 1 through 7.

CAUTION! Ensure power is turned OFF at the breaker

or fuse panel before starting installation.

CAUTION! Ensure power is turned OFF at the breaker

or fuse panel before starting installation.

NOTE: If wall control operation is reversed (fan switch controls lights and

light switch controls fan) turn off the power at the breaker or fuse panel,

then swap the two W-32 black/white stripe wires.

N0TE: If wall control operation is reversed (fan switch controls lights

and light switch controls fan) turn off the power at the breaker or

fuse panel, then swap the two W-32 black/white stripe wires.

INTELI•TOUCH DUAL W-32 INSTALLATION

INTELI•TOUCH SINGLE W-32 INSTALLATION

INTELI•TOUCH INSTALLING THE W-32 WALL CONTROL

Inteli•Touch

®

R