IR TV Controller

Command

Description

Tuner Mode

SO "$A5,<dh>,<dl>,3,'S0',<tune mode>" (7 bytes)

Sets tuner mode to CATV or Broadcast/Antenna

0 = CATV

1 = Broadcast/Antenna

2 = HRC

Tune Ring

TR “$A5,<dh>,<dl>,<ncb>,’TR’, [<chan 1>, <chan N>]” (variable bytes)

This command stores a Tune Ring, a series of preset channels accessed by channel

up/down commands.

Ex1: “$A5,<dh>,<dl>,6,’TR’, 5,4,8,11” sets ring to channels 5, 4, 8 and 11

Tip: The ring follows the stored order, channels do not have to be in ascending

order

x Ex2: “$A5,<dh>,<dl>,2,’TR’ ” clears the Tune Ring, locks unit to current channel

Tip: In the above mode, the IR Keypad channel up/down response to the Head-

End, so the system will know the user is trying to change channels. In

response, the system could change channels on a media sources, like a VCR or

satellite.

Ex3: “$A5,<dh>,<dl>,8,’TR’, $82,5,$87,11” sets channels 2-5 and 7-11. You can

specify a range using MSB bit for the first channel; the next byte is the last.

Channel Labels TN “$A5,<dh>,<dl>,<ncb>,‘TN’,<channel>,<label>” (variable bytes)

Stores an ASCII string as the channel label. The text will appear briefly when the

channel is selected, if the feature has been activated by IRC Setup command (TM).

Ex1: “$A5,<dh>,<dl>,3,‘TN’, ‘7’, ‘PBS’ ” IRC displays PBS when 7 is selected

Ex2: “$A5,<dh>,<dl>,3,‘TN’, ‘7’ ” Clears alpha label for channel 7

Ex3: “$A5,<dh>,<dl>,3,‘TN’,0,0” Clears all alpha labels

Display Label

TC “$A5,<dh>,<dl>,2,’TC’ ” (6 bytes) – Display current channel label for about 15

seconds

Closures Y-

“$A5,<dh>,<dl>,3, ‘Y’ <I/0 Port>’ ” (7 bytes)
Turns the two internal closures on and off. Closure 1 is typically used to control the

optional buzzer, Closure 2 typically used to control an external camera power relay.

“$A5,<dh>,<dl>,3, ‘Y10’” turns Closure 1 off

“$A5,<dh>,<dl>,3, ‘Y11’” turns Closure 1 on

“$A5,<dh>,<dl>,3, ‘Y20’” turns Closure 2 off

“$A5,<dh>,<dl>,3, ‘Y21’” turns Closure 2 on

Control Lock

LM “$A5,<dh>,<dl>,3,'LM',<control>” (7 bytes)

Locks out front panel and IR remote control functions.

Bit 7 Selects IR remote control operation (0=enabled, 1=disabled)

Bit 6 Selects volume control operation (0=enabled, 1=disabled)

Bit 5 - 1 Always 0

Bit 0 Selects IRC front panel buttons operation (0=enabled, 1=disabled)

Device Status

SP "$A5,0,0,3,'SP'" (6 bytes)

Queries the Head-End for the number of devices present on the network and the

number of devices expected.