8

IR TV Controller

On-Screen Setup Menus

The remaining installation steps use the IR remote and the built-in character generator of the IRC.

1. Touch Menu, then 999, then Enter.

2. The text CR MENU> should appear on the screen.

3. Key in one of the commands shown below, then press Enter to activate.

4. Note that, in Menu mode, the Channel Down key acts as a backspace/delete key.

Command Function

All

The following commands are used for all IRCs

45678

Display IRC firmware version

45679

Display the unit’s Device #. At this point, you can use the Channel Down key as a

Delete key, enter a new device # with the remote’s numeric keypad, then hit Enter

to save the new number.

45700

Display or edit IR device type. Sets the IR control format to match your TV. In many

cases, CR can pre-set this command to the format specified by the dealer.

0=None

1=Zenith [added V2.0]

2=Panasonic [added V1.7]

3=Toshiba [added V2.0]

4=Hitachi [added V2.0]

5=Sony [added V2.0]

6=Grundig [added V2.0]

7=Magnavox/Philips [added V1.7]

8=RCA [added V2.0]

9=Sony_2 [added V2.0]

10=Panasonic_2 [added V1.9]

11=Mitsubishi [added V2.0]

12=Monivision (old) [added V1.6]

13=Monivision (new) [added V1.8]

14=Panasonic_3 [added V1.9]

15=Sharp [added V2.1]

16=Pioneer (plasma) [added V2.3]

17=NEC (plasma) [added V2.3]

18 = Samsung [added 2.5]

45702

Set IR receive, IR output and power sensing levels.

1 = Enable 38KHz IR receive in, 0=disable

2 = Enable 57KHz IR receive in, 0=disable

4 = Enable IR output carrier, 0=no carrier

8 = Set power sensor for high sensitivity, 0=low sensitivity

16 = Set IR output for high current, 0=low current

Add up the values and enter the result. For example, the default setting is 30 (57

KHz on, IR carrier, high power sensitivity, and high IR output).

65478

Reset IRC, similar to disconnecting power then restarting.

65487

Initialize IRC to factory default settings: Power on, unlocked, display channel 11,

channel ring set to 4, 5, and 11, Group 0. Note that this command works even if TV

power is off or control is locked out.

65482 Shows

Net RX if receiving the iC-HE’s “heartbeat” pulse once per second, !NET RX

if not. Also displays receive signal strength in the ICC2-IRC.

ICC2-IRC

The following commands are used for the ICC2-IRC only

65480

Enable constant Net transmit to the Head-End. This is used for measuring the signal

strength of the ICC2-IRC’s RF output. Press Enter to stop transmitting, or the unit

will automatically stop after 50 seconds.

65481

Display ICC2 transmitter frequency control voltage – should be 2000 - 3150.

65483

Display DF transmitter frequency deviation – should be 245 - 300.