Contemporary Research ICC2-IRC User Manual

Page 5

Advertising
background image

Contemporary Research Corporation

5

IR TV Controller

RF Tuner

Frequency Range: NTSC television 55.25 to 801.25 MHz, 62.5KHZ fine tune resolution

Maximum Input:

+20dBmV

Video Gain:

±5% maximum, 2% typical

Video Phase:

±3 degrees maximum, 2 degrees typical

iCC-Net (ICC2-IRC)

Operation:

Carried over the same RF coax connection as TV channels

Data Receive:

Mid-band VHF, 74.7MHz, sent from IC Head-End Network Controller

-25 to +35 dBmV signal level

Data Transmit:

Sub-band, 5.6MHz sent to Head-End Network Controller

±

80 KHz max carrier deviation

+49dBmV nominal

iCW-Net (ICW-IRC)

Connector

RJ-45 female 8 pin Telco jack

RS-485 type data requiring at least 2 twisted wire pairs with shield or fifth conductor

Recommended Wire: CAT3/CAT5 compatible unshielded, max 3300 feet [914m] from iC Head End

CC-HSD Scan Sensor
Range:

Senses presence of TV scanning, from 15-35 KHz, magnetic pick-up

Includes:

3.5mm plug, 4ft. cable, stick-on TV sensor


Status Indication

The Net and Power LEDs have special modes that help system setup and troubleshooting.

Power LED

Uses a blink mode when the IRC logic and Sensor feedback do not agree

For example, if the TV Controller knows the TV should be on, but the sensor

input does not see scanning activity, the Power LED blinks rapidly.

Net LED

Blinks when it is receiving network data

LED Response
Off – DC power to IRC missing or other internal power problem
Solid On – no network communication
Blinks once per second - communicating over network

The Head-End Network Controller sends out a “heartbeat” command once every

second that will flash the Net LED.

Logic Sensor LED

Response

ON ON

Solid

On

ON

OFF

Blinks – states do not agree

OFF OFF Solid

Off

OFF

ON

Blinks – states do not agree