Problem: kgl-25 kettle won't heat – Cleveland Range KCL-25-T User Manual

Page 32

Advertising
background image

29

PROBLEM:
KGL-25
Kettle Won't
Heat

Does red light

come on when unit

is first turned on?

Does red light go

off shortly after

unit is turned on?

Yes

Add water to

jacket of Kettle.

With the

potentiometer set

at 10, is 12 VDC at

the coil of the

relay?

No

Yes

Is 16 VAC

measured across

Pins 9 and 10 on

the controller?

No

Yes

Is 16 VAC at the

secondary side of

the transformer?

No

Replace

the on/off

switch (toggle

or rotary).

Yes

Is there 115 VAC

to the primary of

the transformer?

No

Replace the
transformer.

Yes

Supply115

VAC to the

kettle.

No

Does the relay pull

in?

Yes

Replace the

relay.

No

Is there 115 VAC

to the primary of

the ignition

transformer?

Yes

No

Replace the

high limit.

Replace

the Ignition

module.

Is there 24 VAC to

the ignition

Module?

Yes

Replace the

ignition

transformer

No

Is there 24 VAC to

the Gas valve for 4

Seconds?

Yes

No

Is there Gas to the

burner?

Yes

If there

is spark and gas to

the burner assmbly

there should be

flame. Check

alighnment.

Yes

With a jumper

across pins 5 and

7 on the controller,

is there 12 VDC

across the coil of

the DC relay?

No

With the jumper

removed and the

probe wire

grounded at the

probe, is 12 VDC
measured across

the coil of the DC

relay?

No

Replace the

wire harness in

the trunion

No

Add water

Yes

Does the

potentiomer have

a resistance of

50,000 ohms on

low and 0 ohms at

high?

Yes

Replace the

potentiometer

No

Does the probe

have a resistance

of 100,000 ohms +

10% at room

temperature?

Yes

Replace the

controller

Yes

Replace Probe

No

Replace the

gas valve

No

Is there Spark to

the ignitor for 4

seconds.

No

Yes