Problem: kgl-25 kettle not hot enough – Cleveland Range KCL-25-T User Manual

Page 33

Advertising
background image

30

PROBLEM:
KGL-25
Kettle Not
Hot Enough

With kettle pot

empty and

temperature knob

set at 10, is the

temperature of the

surface of the pot

260 degrees?

Unit is

operating

properly

Yes

When unit is cold

(room temp) is the

pressure gauge in

the green?

No

Vent

the kettle per
instructions in

the manual.

No

When the unit is

calling for heat

(the green light is

on), is there flame

at the burner?

Yes

Yes

Is the resistance of

the thermister

100,000 ohms

+10% at room

temperature?

Replace the

thermister.

No

Is the

potentiometer

resistance 50,000

ohms at low and 0

ohms at high?

Yes

Replace

controller.

Yes

Replace the

potentiometer.

No

Does the kettle

heat at all?

Yes

See Problem:

kettle won't heat.

No

Is there 115 VAC

to the primary of

the ignition

module?

No

Is there 24 VAC to

the ignition

module?

Yes

Yes

Replace the

igniton

transformer

No

Replace the

high limit

No