Warning, Leak check, Mantles – Coleman 5040-761 User Manual

Page 9

Advertising
background image

9

Leak Check

WARNING

• Perform all leak tests outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the heater until all connections have been leak tested and

do not leak.

Lift cover while installing

remaining cylinder cover section.

Hose/Regulator

Connection

Regulator/Cylinder

Connection

Complete installation.

• Make 2-3 oz. of leak check solution (one part liquid dishwashing
detergent and three parts water).
• Apply several drops of solution where hose attaches to regulator.
• Apply several drops of solution where regulator connects to Cylinder.
• Make sure all Patio Heater & Light valves are OFF.
• Turn Cylinder Valve ON.
If bubbles appear at any connection, there is a leak.
• Turn Cylinder Valve OFF.
• If leak is at Hose/Regulator connection: tighten connection and perform
another leak test. If you continue to see bubbles after several attempts,
contact 1-800-835-3278 for assistance.
• If leak is at Regulator/Cylinder Valve connection: disconnect, reconnect,
and perform another leak check. If you continue to see bubbles after sev-
eral attempts, cylinder valve is defective and should be returned to cylin-
der’s place of purchase.
If NO bubbles appear at any connection, the connections are secure.
• Turn Cylinder Valve OFF.
NOTE: Whenever gas connections are loosened or removed, you
must perform a complete leak test.

Mantles

Remove 2 glass panels.

Slip mantle onto burners. Align clips in mantle with groove in burner. Be

sure clip points away from electrode.

Twist clips.

Electrode

Groove

Advertising
This manual is related to the following products: