Others, Pe rfo rm ance d at a shee t | ch p-03a r – Coway CHP-03AR User Manual

Page 33

Advertising
background image

State of California

Department of Public Health

Water Treatment Device

Certificate Number

08 - 1867

Date Issued: June 24, 2008

Trademark/Model Designation

replacement Element(s)

Mach CHP-03AR

WJNF11 Neo-Sense Filter

WJMF11-50 RO Membrane Filter

WJCF11-POST Post-carbon Filter

WJFF7 Fine Filter

WJCC-02 Ceramic Filter

M

anufacturer: Woongjin Coway Co LTD

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section

116830 of the Health and Safety Code for the following health related contaminants:

Microbiological Contaminants and Turbidity

Inorganic/radiological Contaminants

None

Arsenic (Pentavalent)

1

Barium

Cadmium

Chromium (Hexavalent)

Chromium (Trivalent)

Lead

Nitrate/Nitrite

2

Radium 226/228

Selenium

Organic Contaminants

VOCs

Alachlor

Endrin

Simazine

Atrazine

Ethylbenzene

Styrene

Benzene

EDB

1,1,2,2-Tetrachloroethane

Carbofuran

Haloacetonitriles (HAN)

Tetrachloroethylene

Carbon Tetrachloride

Bromochloroacetonitrile

Toluene

Chlorobenzene

Dibromoacetonitrile

2,4,5-TP (Silvex)

Chloropicrin

Dichloroacetonitrile

Tribromoacetic Acid

2,4-D

Trichloroacetonitrile

1,2,4-Trichlorobenzene

DBCP

Haloketones (HK)

1,1,1-Trichloroethane

o-Dichlorobenzene

1,1-Dichloro-2-Propanone

1,1,2-Trichloroethane

p-Dichlorobenzene

1,1,1-Trichloro-2-Propanone

Trichloroethylene

1,2-Dichloroethane

Heptachlor

Trihalomethanes (THMs)

1,1-Dichloroethylene

Heptachlor Epoxide

Bromodichloromethane

cis-1,2-Dichloroethylene

Hexachlorobutadiene

Bromoform

trans-1,2-Dichloroethylene

Hexachlorocyclopentadiene

Chloroform

1,2-Dichloropropane

Lindane

Chlorodibromomethane

cis-1,3-Dichloropropylene

Methoxychlor

Xylenes

Dinoseb

Pentachlorophenol

rated Service Capacity: 229 gal

rated Service Flow: 0 .07 gpm

Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection

before or after the system .

1

Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at the

reverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1minute
chlorine contact time before the RO system.

2

This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in

combination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa
(40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of this system.
Frequent analysis is encouraged.

pE

rFO

rM

ANCE D

AT

A SHEE

T

| CH

p-03A
r

O

thers

32

Advertising
This manual is related to the following products: