DEHUMIDIFIER FEATURES (CONTINUED)

OTHER FEATURES
Bucket Full Light

Illuminates when the bucket is ready to be emptied.
Automatic Shut Off

The dehumidifier shuts off when the bucket is full,

removed, or not placed in the proper position. When

the desired humidity setting is reached, the unit will

cycle off automatically. For some models, the fan

motor will continue operating.
Automatic Defrost

When frost builds up on the evaporator coils, the

compressor will cycle off and the fan will continue to

run until the frost disappears.
Wait 3 Minutes Before Resuming Operation

After the unit has stopped, it cannot begin operating

again for 3 minutes. This is to protect the unit.

Operation will automatically resume after 3 minutes.
Check Filter Feature

The check filter light will automatically flash (once per

second) when the accumulated operation time

reaches 250 hours of operation or more. The system

starts to count the operation time once the fan motor

operates. After you finish cleaning the air filter, press

the Filter pad; the Filter indicator light clears.
Automatic Restart

If the unit breaks off unexpectedly as the result of

having the power cut, it will automatically restart with

the previous function setting when the power resumes.

Setting the Timer
If setting the timer when the unit is on:

First press the TIMER button; the TIMER OFF

indicator light illuminates. It indicates the Auto Stop

program is initiated. Press the TIMER button again;

the TIMER ON indicator light illuminates. It

indicates the Auto Start program is initiated.
If setting the timer when the unit is off:

First press the TIMER button; the TIMER ON

indicator light illuminates. It indicates the Auto Start

program is initiated. Press the TIMER button again;

the TIMER OFF indicator light illuminates. It

indicates the Auto Stop program is initiated.
- Press or hold the UP or DOWN button to change the

Auto time by 0.5 hour increments, up to 10 hours

then at 1 hour increments up to 24 hours. The

control will count down the time remaining until start.

- The selected time will register in 5 seconds and

the system will automatically revert back to

displaying the previous temperature setting.

- When the start and stop times are set within the

same program sequence, the TIMER ON and OFF

indicator lights both illuminate, identifying both ON

and OFF times are now programmed.

- Turning the unit ON or OFF at any time or

adjusting the timer setting to 0.0 will cancel the

Auto Start/Stop timed program.

- When the LED display window shows the code

P2, the Automatic Start/Stop function will also

be canceled.

ERROR AND PROTECTION CODES:

AS - Humidity Sensor Error - Unplug the unit and plug

it back in. If error repeats, call customer service.

ES - Temperature Sensor Error - Unplug the unit

and plug it back in. If error repeats, call

customer service.

P2 - Bucket is Full - Empty the bucket.
Eb - Bucket is removed or not in correct position -

Replace the bucket in the proper position.

EC - Unit Malfunction - Please make sure the

temperature of the environment is suitable for

the proper operation of the unit. The unit should

be operated in an environment from 41ºF (5ºC)

– 95ºF (35ºC). If the unit’s location falls in this

temperature range and you continue to get the

EC error code, call customer service.

E3 - Unit malfunction - Unplug the unit and plug it

back in. If error repeats, call customer service.