Progressive Industries EMS-PT50C User Manual

Page 3

Advertising
background image

Warnings

Do not exceed the rating on the EMS for any reason,

however, these devices are designed to be reduced down to

120V/15A, and still maintain full protection.

Do not modify the EMS in any way, this will void the

warranty, compromise protection, and could result in

possible shock, and/or a fire hazard.

It is important to always check the pedestal power outlet for

charring; this condition means that the AC receptacle is

providing a weak connection. DO NOT USE! It could

result in possible melting of the RV power plug.

When running extension cords from the RV to AC power,

always use a 6-gauge cable for your 240V, 50 Amp system.

Make sure that the cable is rated for outdoor use to reduce

the risk of electric shock. Small gauge cable will have a

higher resistance and will result in a voltage loss, plus it

may result in an electrical fire.

Whenever servicing or installing the EMS or any other AC

powered device, make sure AC power is disconnected.

RV wiring is different than the wiring found in homes; the

neutral and ground conductors are isolated in the RV,

unlike in a home where they are tied together at the service

panel. The reason is: homes have a bonded ground

system, whereas RV’s do not. Therefore, never bond the

neutral and ground together for any reason. This will

create a ground fault condition, and may result in electric

shock and/or a fire hazard.

Never

plug the EMS into an inverter.