Operating instructions – Progressive Industries EMS-PT50C User Manual

Page 4

Advertising
background image

Operating Instructions

1.

Plug into AC power.

2.

Digital display will read 888 for one second then begin

scrolling the voltage, amps, line frequency, and error

code(s). In addition, the time delay light will flash in

the bottom right corner of the display.

3.

The EMS will read L-1, and then give you a 3-digit

number which is your line voltage. Next, it will give

you an “OA” reading. This is the amp reading;

however, it will read zero until the time delay is

complete. Then you will notice a number between 0

and 35. That number indicates how many amps the RV

is drawing. Next, the display will read L-2 and indicate

the voltage and amps for Line 2. Then it will read 60H

and this number should remain fairly consistent;

however, it may read plus or minus one or two. Lastly,

you will notice the E code. E-0 is normal. Only when

an E-0 and E-10 is present will the delay light flash and

ultimately bring power in to the RV. Refer to your

Error Code Chart that is provided or see next page for

details.

4.

Verify that Error Code E-0 is displayed.

5.

Set up is complete.

6. The EMS has a 136-second time delay before you will

receive power into your RV.


IMPORTANT:

The display will only read voltages between

78 volts and 255 volts.


Note

: If the wiring reads anything different than correct, the

EMS will not turn on and we recommend moving to a different

source of AC power, or you use your generator power. Also, if

power is below 104 volts or above 132 volts, the EMS will not

turn on, and we recommend using your generator power.

Advertising