GYROSCOPE AND ACCELEROMETER CALIBRATION

The internal three-axis gyroscope and three-axis accelerometer need to be calibrated for the Horizon overlay

to function properly. The Gyro/Acc calibration file is stored in the flash memory of the BRAIN, so you DO NOT

need to recalibrate after restoring the camera or upgrading firmware. For more information, go to

“Horizon” on

page 66

.

To calibrate the Horizon overlay, follow the instructions below:
1. Turn on the BRAIN and place it on a level surface.
2. Wait for the camera core temperature to reach room temperature.
3. Go to Menu > Settings > Maintenance > Calibration > Gyro/Acc and select Low Temperature Calibration.
4. After the calibration finishes, wait for the camera core temperature to reach maximum operating temperature.
5. When the BRAIN reaches maximum operating temperature, select High Temperature Calibration.

LENS CALIBRATION

There are many electronic lenses that are compatible with the DSMC Canon Mount or DSMC Nikon Mount, but

are not electronically supported by the DSMC. The Lens Calibration feature allows you to create custom lens

configuration files for these electronic lenses so that you can use rack focus and autofocus.
A custom configuration file might not make an unsupported lens as precise as a fully supported lens. However,

a custom configuration file provides the F stop range and focal lengths so that you can electronically control

the lens with the camera.
NOTE: The camera may not be able to calibrate some electronic lenses.
NOTE: The camera does not create calibration files for lenses that are already electronically supported. For a full