TROuBlESHOOTINg

Do not operate the steam cleaner with a damaged electrical cord, plug or if the
steam cleaner has been dropped or damaged. To avoid risk of electric shock, do not
disassemble or attempt to repair the unit on your own. Return the unit to Reliable
Corporation (see warranty) for examination, repair or replacement.

EP1000 TROllEy ASSEMBly INSTRuCTIONS

1. Trolley base unit
2. Tray to carry accessories
3. Trolley handle
4. Rotating wheels (2)
5. Back wheels (2)
6. Chrome back wheel cover (4)
7. Self locking nuts (2)
8. Washers (4)
9. Brass wheel cover (2)
10. Fixing cap (4)
11. Water bottle with tap
12. Transparent silicone hose
13. Cap
14. Wrench

10

(PROBLEM) There is no steam, all the lights remain on and the pump is continuously running.
(POSSIBLE CAUSES) 1. You're using too much steam (pos. 4). 2. Water pump is broken.
(REMEDY) 1. Turn off main switch (1) wait 1 minute then turn back and wait for green light (A)
to turn on. 2) Contact Reliable Corporation for service.

PROBLEM

No steam is released through
the steam fittings.

Water drops leak from the
attachments.

Dirty water is coming out.

Not enough steam pressure.

REMEDY

1. Turn on main switch (1)
2. If the red light (B) is flashing

on and off and you can hear
a noise, fill up the tank.

3. Plug unit into outlet
4. Wait for the green light (A)

to turn on.

1. Wait for light (A) to turn on.
2. Let water run through sys-

tem until steam comes out.

1. Follow cleaning instructions

in book.

1. Turn the dial until the de-

sired pressure is reached.

POSSIBLE CAUSES

1. Steam unit is not turned on.
2. Water tank is empty.
3. Unit is not plugged in.
4. Generator is not fully

heated.

1. Unit is not fully heated.
2. Condensation was created

from non-use.

1. Scale may have built up.

1. The dial on the handle may

be set too low.

Advertising