Form I-ADF, Page 8

FIGURE 3 - Cross Support Mounting Requirements

Field

Supplied

Duct

Field

Supplied

Duct

4 x 4 Treated Lumber

= support location

5.0 Mounting

(cont'd)

5.3 Mounting on

Field-Supplied

Supports

(cont'd)

5.4 Mounting on a

Roof Curb

CAUTION: Before assembly, re-check to be sure that the correct

curb has been ordered. Be sure that the curb selected matches

the unit ordered. Verify the dimensions of the curb received with

the curb dimension table, FIGURE 4.

Installation Instructions for 16" Optional Roof Curb (Option CJ3) - Refer

to FIGURE 4

NOTE: Curb rail sections and hardware for assembling curb are provided with

optional roof curb. Insulation and flashing are field supplied.
1. Position the curb cross rails as shown in the assembly illustration in FIGURE 4.

Fasten curbing pieces with bolts and lag screws as illustrated in the corner detail.

2. Check the assembly for squareness. The curb must be adjusted

so that the diagonal measurements are equal within a tolerance of ± 1/8".

3. Level the roof curb. To ensure a good weatherproof seal between the curb cap and

the roof curb, the roof curb must be leveled in both directions with no twist end to

end. Shim as required and secure curb to roof deck before installing flashing.

4. Install field-supplied flashing.
5. Before placing the unit into position, apply furnished 1/4" x 1-1/4" foam sealant

tape to the top surface of the curb, making good butt joints at the corners. The

unit must be sealed to the curb to prevent water leakage into the curb area due to

blowing rain and capillary action.

FIGURE 4 - Optional Roof Curb (Shipped separately to be field assembled)

B

D

A

C

1-7/8

(48)

16 (406)

1-7/8 (48)

1-7/8

(48)

16”

(406mm)

1-7/8”(48mm)

(102mm)

2 x 6 Wood Nailer

1-1/2 x 3 lb

Fiberglass

Flashed by the

installer (flashing must

be under lip of curb)

Lag Screw

Cap

Screws

IMPORTANT: Area enclosed by roof curb must comply with clearance to combustible

materials.If roof is constructed of combustible materials, area within curb must be either

ventilated, left open, or covered with non-combustible material which has an "R" value of

at least 5.0. If area within curb is left open, higher radiated sound levels may result.

Curb Layout and Dimensions

Curb Detail

Corner Detail

Advertising