WIRING DIAGRAMS

TankWaTCh 4 Tank LeveL MoniTor SySTeM reCoMMended

Wiring for waste water and gray water TankS.

USe 18ga. STranded Copper Wire or Larger.

Please note ThaT The reCeSSed ShoULder, The

WhiTe Band, or The LeTTerS "n-o" of The fLoaT

are doWnWard on The eMpTy fLoaT.

TankWaTCh 4 Tank LeveL MoniTor SySTeM reCoMMended

Wiring for water tanks.

USe 18ga. STranded Copper Wire or Larger.

Please note ThaT The reCeSSed ShoULder, The

WhiTe Band, or The LeTTerS "n-o" of The fLoaT are

doWnWard on The eMpTy and 1/4 Mid fLoaT.

OPTIONAL PLuG-IN RELAY WIRING DIAGRAM

USe 12 or 14 gaUge Copper STranded Wire.

WiTh reLay inSTaLLed, and The TankWaTCh 4 Wired for a WaSTe

(BLaCk) WaTer Tank, The Tank fULL fLoaT SWiTCh WiLL ShUT off

eLeCTriCaL poWer To The ToiLeT SySTeM. When The TankWaTCh 4

iS Wired for a freSh WaTer Tank, The eMpTy fLoaT SWiTCh WiLL

ShUT off The WaTer pUMp When The Tank iS eMpTy.

OPTIONAL “DO NOT fLuSH” PANEL WIRING DIAGRAM

USe 16 or 18 gaUge Copper STranded Wire.

Up To foUr (4) “do noT fLUSh” paneLS Can Be USed WiTh

one TankWaTCh 4 indiCaTor paneL.

pin 1 for 12vdC SySTeMS

pin 2 for 24vdC SySTeMS

*

Consult toilet or water system specifications for

proper fusing or circuit breaker size.

do not exceed 30 amps.

*