Encore nc clearance chart, Unprotected surfaces protected surfaces – Vermont Casting 1450 User Manual

Page 15

Advertising
background image

15

Encore 1450 Non-Catalytic Woodburning Stove

30002425

21” (533 mm)

7” (178 mm)

9” (229 mm)

3” (76 mm)

3


6” Connector

8” Connector

15” (381 mm)

9” (229 mm)

*

(A) 17”

(B) 29”

(C) 28”

(D) 8”

1,4

(E) 15”

1,4

(F) 8”

1,4

(432 mm)

(737 mm)

(711 mm)

(203 mm)

(380 mm)

(203 mm)

(G) 17”

(H) 17”

(I) 19”

(J) 8”

1

(K) 11”

1

(L) 7”

1

(432 mm)

(432 mm)

(483 mm)

(203 mm)

(280 mm)

(178 mm)


(M) 18”

(N) 24”

5

N/A

(P) 8”

(Q) 6” Collar

N/A

(457 mm)

(610 mm)

(203 mm)

11” (279 mm)

8” Collar

19” (483 mm)


(G) 18”

(H) 6” Collar

(I) 19”

(457 mm)

23” (584 mm)

(483 mm)

*

8” Collar

17” (432 mm)

Stove Clearance

Unprotected Surfaces

Protected Surfaces

Chimney Connector Clearance

Single-wall connector,
No chimney connector
heat shields

Single-wall connector,
Chimney connector heat
shields installed

Double-wall connector

Clearance to Combustibles in Front of Stove

All Installations

(S) 48” (1219 mm)

* Clearances with double-wall connectors and protected surfaces have not been tested for the Encore NC.
1. A ceiling heat shield, 24” (610 mm) in diameter and suspended 1” (25 mm) from the ceiling, must surround the chimney connec-

tor in installations in which the chimney connector penetrates the ceiling.

2. The chimney connector shield extends only to 36” (914 mm) above the flue collar.
3. The ceiling heat shield required when the chimney connector shields are used should meet the wall protector. This will require

trimming the ceiling shield along the line of intersection with the wall protector.

4. The vertical collar heat shield is not required when wall protection is installed according to this manual.
5. All rear exit installations require a wall shield when combustible material is within 12” (305 mm) of the center of the rear wall

pass through. The shield must be 24” (610 mm) in diameter, be spaced 1” (25 mm) from the wall and must surround the chim-
ney connector.

Encore NC Clearance Chart

For use with either 6” or 8” flue collar/chimney connection

Stove Installed

Stove

Stove Installed

Stove

Parallel to Wall

in Corner

Parallel to Wall

in Corner

Side

Rear

Corners

Side

Rear

Corners

No stove heat shields,
vertical flue collar heat
shield installed (except
where noted)
Top Exit, single-wall
chimney connector heat
shields

2

, vertical flue col-

lar h.s. installed

Rear Exit

Top Exit, double-wall
chimney connector,
vertical flue collar heat
shield installed