To Replace Battery Backup Batteries

1. Disconnect telephone line cord and

remove desk/wall mount bracket from

telephone base.

2. Disconnect battery back-up connector from

the telephone base.

3. Remove batteries from desk/wall

mount bracket.

4. Install four (4) AA Alkaline batteries with

negative (-) end of battery touching

the spring.

5. Connect battery back-up connector to

terminal on bottom of telephone base

6. Install desk/wall mount bracket to

telephone base

After installing the four (4) AA Alkaline batteries
please refer to the chart below:

Power Supply

Power LED Status

AC adapter and

Steady Green

good batteries

AC adapter and

Steady Red

no batteries

AC adapter and

Flashing green and red

bad batteries

Power failure and

Slow flashing red

good batteries

Power failure and

Fast flashing red

bad batteries