SOLBERG

B. The vane/demister pack will lift out of basket assembly

C. After cleaning, re-install by pressing pack into the basket assembly. Tighten

fasteners on retaining ring until secure

6. Securing Vessel Lid

A. Make sure all surfaces are free from dust and other particulate.

B. O-rings (when present) must rest evenly along the o-ring groove on the vessel

ring flange

C. Gaskets (when present) must rest flat and even along vessel ring flange

D. Install fasteners and tighten to torque specification supplied on drawing

Section D

MAINTENANCE RECOMMENDATIONS

1. Recording the initial differential pressure readings is recommended to effectively

maintain a scrubber/separator. Always document initial differential during start-up
when element is clean and after two weeks when element is dirty or saturated.
Replacement filters are needed when system experiences the maximum differential
pressure levels specified by the Operator. Refer to pages 4 and 5 for guidelines

2. Always check replacement o-rings/gaskets to insure they are seated uniformly along

the flanges during installation. If o-rings/gaskets do not seat properly or are
damaged, please contact Solberg Manufacturing, Inc. immediately

3. Always check inlets/outlet connections, sealing surfaces and hardware when

replacing the element to insure cleanliness. Wipe clean if necessary

4. Always ensure vane/demister pack is aligned and installed correctly within mounting

basket

5. Operate only when a proper seal exists

6. Never operate without absolute assurance that fasteners have been tightened to the

specified torque rating