I N S T R U C T I O N M A N U A L • M O D E L G X L P O W E R S U P P LY

15

5. DISTANCE key which allows selection and display of distance settings

and permits adjustment of the following distance parameters in .001 inch

increments (from 0.000 to 9.999 inches, or 0.000 to 253.975 millimeters):

a. Distance Incremental

b. Distance Absolute

c. Distance Limit Low

d. Distance Limit High

e. Pre-weld Limit Low

f. Pre-weld Limit High

g. Pre-Trigger Distance

For a complete explanation of these parameters, refer to page 21.

6. ENERGY key allows selection and display of the following energy

settings and permits adjustment of the energy parameters a. through c.

below in 1 joule increments (from 0 to 999,999 joules):

a. Energy Setting

b. Energy Limit Low

c. Energy Limit High

d. Calibration Pulse (on/off)

For a complete explanation of these parameters, refer to page 23.

7. AMPLITUDE/PRESSURE key which controls adjustment of the

following amplitude and pressure settings of the system’s high-frequency

vibrations over the full operating range. (Major adjustments of amplitude

can be made through the use of different boosters – consult your press

manual for further information.)

a. Amplitude Setting

b. Amplitude Ramp (only on systems configured for more than 2200

watts)

c. Trigger Force (Press)

8. TRIGGER key which displays and permits selection of the trigger mode

from the following options –

a. Delay Timer

b Force/Pressure

c. Distance