Sonics GXL User Manual

Page 39

Advertising
background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T R U C T I O N M A N U A L • M O D E L G X L P O W E R S U P P LY

37

Item 5: The maximum percent power number is next in line at positions 36

through 38 with a space at 39. This number is the maximum percent of

power developed during the last weld cycle. The label “%Pmax” does not

change case as the control items can for time, distance and energy. It is not

a control parameter, just a label for text readability.

005647 00.48 sec 0.025 in 000130 J

045 %Pmax

Alarms T:-- D:-- E:-- J06 -----

Item 6: Any alarm violations for time, distance or energy will be sent in the

following positions as L or H in place of the “--” shown in the sample line.

The dashes are used to hold the place when there are no alarm items so the

“T:-- D:-- E:--” reading indicates that there were no alarms during the last

weld cycle. The low alarm, high alarm order is always the same for time,

distance and energy (examples: T:L- T:-H or T:LH ). Time alarms are at

positions 57 and 58; distance at positions 62 and 63; and energy at positions

67 and 68. Note that it is possible for a weld cycle to have both high and low

alarms at the same time depending on the alarm settings (see pages 17-23).

High and Low alarms are set and examined independently.

005647 00.48 sec 0.025 in 000130 J 045 %Pmax

Alarms T:-- D:-- E:--

J06 -----

Item 7: The next item represents the last job number that was saved or

recalled from the job storage memory. There are 15 jobs numbered 1 through

15 so this item is transmitted as 01 through 15 or “--” if job data has not been

set (first power up). The “J” label is used for readability of the job data

number. When an automation system is using the remote job change option

between weld cycles, the print line can be used as verification of the recalled

job for the last weld cycle. The job data number is located at position 71

through 72.

005647 00.48 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:--

J06

-----

Go To Top Of Document

Advertising