I N S T R U C T I O N M A N U A L • M O D E L G X L P O W E R S U P P LY

25

TRIGGER

Selection of the trigger mode is achieved by pressing the Trigger Key and

then using the Up/Down arrow keys as a toggle to select one of the following

modes to act as the trigger to start ultrasonics.

Delay Timer – selecting this mode means that the ultrasonics will be

triggered when the Delay Time specified in the Time menu is reached.

Force/Pressure – selecting this mode means that the ultrasonics will be

triggered when the Trigger Force (Pressure) specified in the Amplitude/

Pressure menu is achieved.

Distance – selecting this mode means that the ultrasonics will be triggered

when the Pre-Trigger Distance specified in the Distance menu has been

traveled.

Effect of Trigger Selection

The measurement of the precise contact point (the position at which the horn

first contacts the parts), and subsequent Distance Incremental set point may

be affected by the trigger scenario. A better distance reference is produced

the longer the system is allowed to stop moving and come to rest. Using a

Delay Timer trigger will yield the best measurement of the reference contact

point. Using a Force/Pressure trigger will yield a better reference distance

measurement than the Distance trigger. The scenarios described below

illustrate how incremental distance measurement can be affected.

With Trigger Mode set for Distance – If the Pre-Trigger distance setting is

less than the travel distance to the parts, then the ultrasonics will already

be on when the horn contacts the parts. Since ultrasonics are on, the

reference distance measurement is taken immediately (if the system is

welding by incremental distance setpoint) and this is not ideal for reference

capture.

With Trigger Mode set for Delay Timer – If the system has been

programmed with a delay time value greater than 0.00, the system has

more time to stop moving and the reference point measurement will be

even better. That’s why the incremental weld measurement consistency

should improve.

A review of the Basic Weld Cycle Time Line on page 52 gives additional

information on the start/stop/measurement process.