Asc-plus problem chart, Problems with charging, Problems with low-voltage load disconnect – Specialty Concepts ASC-Plus User Manual

Page 17

Advertising
background image

ASC-Plus PROBLEM CHART

:

-

Refer to this chart and the ASC-Plus

PROBLEM DESCRIPTIONS (next page), to help diagnose potential problems based
on the observations of the ASC-Plus and actual battery voltage. The use of a voltage
multi-meter may be helpful.

Problems with charging

CASE

BATTERY VOLTAGE

(use multi-meter at
battery terminals)

CHARGE
LIGHT

“LOAD
DISCONNECTED”
LIGHT

OTHER

ASC-Plus
CASE NOTES
(next page)

1

Low voltage

(9.0 - 13.2 volts)

ON

Day time

See Case 1

(next page)

2

Low voltage

(9.0 - 13.2 volts)

OFF

Day time

See Case 2

3

Moderate voltage

(13.2 - 14.0 volts)

Turns OFF

(too soon)

Day time

See Case 3

4

High voltage

(14.4 - 15.0 volts)

ON

See Case 4

5

High voltage

(14.4 - 15.0 volts)

OFF

See Case 5

6

ON - at night

See Case 6

7

Light going on
and off rapidly

See Case 7

8

ASC-
Plus
buzzing

See Case 8

9

ASC-
Plus hot

See Case 9

Problems with low-voltage load disconnect

CASE

BATTERY VOLTAGE

(use multi-meter at
battery terminals)

CHARGE
LIGHT

“LOAD
DISCONNECTED”
LIGHT

OTHER

ASC-Plus
CASE NOTES
(next page)

10

Very low voltage

(11.5 volts or lower)

OFF

Loads
stay on

See Case 10

11

Low to Moderate voltage

(11.5 - 14.3 volts)

ON

Loads off

See Case 11