ASC-Plus PROBLEM DESCRIPTIONS

(from the ASC-Plus PROBLEM CHART)

ASC-Plus Case 1 - A continuous low voltage condition with good charging during the day

would indicate that the controller is functional but a problem exists with one of the
following:

A problem exists with the system sizing. See SYSTEM IS NOT SIZED CORRECTLY

(Help Note #5)

••

A problem exists with the solar panels. See SOLAR PANEL PROBLEM SECTION

••

A problem exists with the batteries. See BATTERY PROBLEM SECTION

ASC-Plus Case 2 - A low voltage condition with no charging during the day would indicate

one of the following:

The system has no panel input. See BAD CONNECTION: PANEL (Help Note #8)

••

The ASC-Plus may be defective. See CONTROLLER DEFECTIVE (Help Note #12)

ASC-Plus Case 3 - A moderate voltage condition where the charging appears to stop too

soon (below 14.1 volts) would indicate one of the following:

••

The ASC-Plus may have a bad battery connection. Somewhere in the battery connection

there could be a voltage drop that would cause the controller to sense a higher
battery voltage than what actually exists. See BAD CONNECTION: BATTERY (Help
Note #9)

••

Temperature Compensation (Option-A) can change the controller set-points. See

TEMPERATURE (Help Note #4)

••

The ASC-Plus may be defective. See CONTROLLER DEFECTIVE (Help Note #12)

TEST: - Try to monitor the voltage at the ASC-Plus "BATT (+)” and "BATT (-)” terminals when

the controller actually stops charging (CHARGING light goes OFF). If the voltage at the
ASC-Plus terminals is about 14.3 volts then assume a voltage drop along the battery
connection is causing the problem.

ASC-Plus Case 4 - A high voltage condition with additional charging would indicate one of

the following:

The battery voltage may be just under the charge termination set-point and not need to

shut off. See NORMAL OPERATION: CHARGING / NOT CHARGING (Help Note
#1)

••

Temperature Compensation (Option-A) can change the controller set-points. See

TEMPERATURE (Help Note #4)

The ASC-Plus may be defective. See CONTROLLER DEFECTIVE (Help Note #12)

ASC-Plus Case 5 - A high voltage condition (over 14.5 volts) with the solar charging

terminated during the day would indicate the controller is functional but the batteries are
being over-charged by a second charging source. Other charging sources should feature
their own charge regulation.