SC3/15 PROBLEMS:

- Refer to this chart and the SC3/15 PROBLEM NOTES (next

page) to help diagnose potential problems based on the
SC3/15 readings

CASE

BATTERY METER

PANEL METER CHARGE

LIGHT

OTHER

SC3/15
NOTE
(Next page)

1

No Volts (9 on meter)

Day/Night

See Note 1
(next page)

2

No Volts (9 on meter)

Night only

See Note 2

3

Voltage 9-12

No amps

OFF

Day time

See Note 3

4

Voltage 14.7 - 15.0

See Note 4

5

Voltage meter less than
actual battery voltage

See Note 5

6

Voltage meter higher
than actual battery
voltage

See Note 6

7

Voltage reading erratic

See Note 7

8

No amps

ON

Day time

See Note 8

9

Turns OFF
(too soon)

Day time

See Note 9

10

ON - at night

See Note 10

11

Panel meter
moving rapidly

Charge light
may also be
going on and
off rapidly

See Note 11

12

Current meter less
than expected
panel current

See Note 12

13

Changing to
ON or OFF

Front fuse
being
touched or
taken out

See Note 13

14

SC3/15
buzzing

See Note 14

15

SC3/15
hot

See Note 15

Advertising