4

Bezels

Valve

Stem

Screws

Port holes
downward

Main Burner

Control Knobs

Natural Gas Bezel

80007893

Pull the Burner Control Knobs off of Valve Stems.

Remove Screws and Washers that secure each Bezel to the Control Panel. Save removed Bezels for converting back to LP

Tank Gas.

Install new Natural Gas Bezels provided with Kit (see illustration below) in place of old Bezels, on Control Panel and secure

using previously removed Screws and Washers. Assure proper alignment with Control Knob before fully tightening.

Note: New Bezels will change the rotation for the Control Knob to properly control ignition and flames for your grill.

Press Control Knob back onto Valve Stems. Make adjustments to Bezels for free movement of Control Knobs.

Note: Replace only one Bezel at a time.

5

Insert Burners into Firebox Burner openings, then over Valves with burner crossover port holes downward, making sure
Burner engages Valve properly.

See below diagram.
Secure Burners to Burner Brackets with previously removed Hitch Pins. Replace Carryover Tubes and secure with Hitch

Pins previously removed. Reference illustration Step 2.

Correct burner-to valve engagement

Incorrect burner-to valve engagement