1. This gas log set is only to be installed and burned in a fully vented fireplace with a fully functional damper

and chimney that is free of any obstructions. The fireplace must be constructed of non-combustible

materials and approved to burn wood. Warning: Do not burn wood or other material in any fireplace

fitted with a gas log set.

2. To operate this gas log set, the fireplace damper must be fully opened and locked.

3. The smallest or minimum dimension of the chimney flue must be 8 inces in diameter.

• Do not use an Energy Efficient Gas Log Set if it is smaller than 8 inches.

• Do not use an Energy Efficient Gas Log Set if fumes from the burner emerge into the room when the

damper is fully open. This indicates that ther is not adequate draft for our log sets and the gas log set

must not be used until fireplace draft is corrected.

4. This appliance must be installed with a Damper Stop Clamp (Part # 9). When operating this gas log set,

the flue damper must be fully open.

WARNING: Improper use or installation may cause Carbon Monoxide Poisoning. Carbon Monoxide,

which is an odorless and colorless gas, is a by-product of combustion. Caution must be taken to insure

the fireplace is properly vented when logs are in use. To avoid having potentially dangerous fumes enter

the living area, be sure the chimney is drawing properly and has sufficient draft.

5. A fireplace screen must be in place when operating this gas log sete. This screen shall have an opening(s)

for the introduction of combustion air. If the fireplace has glass doors, operate this gas set with the doors

fully opened.

6. The nominal inlet gas pressure for this appliance is 7" water column for natural gas.

7. This gas log appliance and its individual shutoff valve must be disconnected from the gas supply piping

system during any pressure testing at pressures in excess of 1/2 PSIG.

• This appliance must also be disconnected from the gas supply system by closing its individual manual

shutoff valve during an pressure testing at pressures equal to or less than 1/2 PSIG.

A. Remove all ash and debris from floor of fireplace.

B. Open fireplace damper fully and install Damper Stop Clamp with

1/4 x 2" set screw (Part # 9). This clamp is designed to prevent

accidental closure of the damper while in use. (See Figure 2)

• Should Damper Stop Clamp supplied not fit, a permanent Damper

Stop Clamp must be installed that will keep the damper open at a

distance of not less that 1 1/2".

C. Prior to connecting the gas log set, make sure that the gas supply to

the fireplace is completely shut off.

PREFABRICATED

FIREPLACE

MASONRY

FIREPLACE

Figure 2. Damper Stop Clamp

Installtaion of this Energy Efficient Gas Log Set and provisions for combustion and ventilation air

must conform with the National Fuel Gas Code ANSI Z223.1 and applicable local codes.