Fitting the area on/off (implement) sensor, A. b. c – TeeJet LH 1000 User Manual

Page 14

Advertising
background image

F

ITTING THE

LH 1000

LH 1000 O

PERATORS

& F

ITTING MANUAL

14

LH A

GRO

FITTING THE AREA ON/OFF (IMPLEMENT) SENSOR

Typical fitting of the implement sensor on the tractor’s lift arms:

The implement sensor can be fitted in other positions (PTO handle, hydraulic
cylinders, other handles, etc.). There must be movement of minimum 50 mm. The
distance between the sensor and the magnet must not exceed 5 mm.
An electrical signal from, i.e. a sprayer switch box, etc. can be used as the
implement signal. The signal must change to 0V (ground), when the implement is
not working.

+ 12 V

+12 V

+ 12 V

a.

b.

c.

LIFT UP

LIFT

MAIN SWITCH
SPRAYER ON/OFF

SIGNAL

ELECTRIC

SPRAYER FITTING

COMP.

SWITCH

ELECTRIC

VALVE

SIGNAL

SIGNAL

IMPORTANT! Never connect power (+12V) to the brown output on the LH 1000,

as this will damage the LH 1000.