Fieldpilot, Fieldpilot valve hose connections, Install steering output hoses – TeeJet FieldPilot Install John Deere 8x00 User Manual

Page 16

Advertising
background image

www.teejet.com

15

FieldPilot

®

8. FIELDPILOT VALVE HOSE CONNECTIONS

The Pressure port of the FieldPilot Valve

(D)

will be connected to the pressure port on top of the rear tractor

hydraulic block using one hose

(K)

. The T port from the FieldPilot Valve

(D)

will be connected to the open

fitting on the tank return port on the top of the rear tractor hydraulic block using the second hose

(K)

. The LS

port on the FieldPilot Valve

(D)

will be connected to the open fitting at the load sense port on the top of the

rear tractor hydraulic block using hose

(L)

. Refer to the hydraulic diagrams to understand how the FieldPilot

Valve

(D)

should fit in the system.

Figure 1-11: Install FieldPilot Valve Hoses

K

L

9. INSTALL STEERING OUTPUT HOSES

Kit hoses

(J)

are first connected to the A and B steering ports on the FieldPilot Valve

(D)

.

Figure 1-12: Install Steering Output Hoses

J