12

www.teejet.com

FieldPilot

®

Specific Cautions

The two adapters

(U & X)

look almost identical and can be easily confused with each other. Adapter

(X)

has

metric threads and can be identified by the raised O-ring flange as indicated in the picture. If adapter

(X)

has a

metal washer included, it must be removed before installing adapter

(X)

.

Figure 1-6: Preparing the FieldPilot Valve

U

X

1. PrePare the FieldPilOt ValVe

Install adapter

(Y)

in the A, B, P and T ports of the FieldPilot valve. Install adapter

(V)

in LS port.

Figure 1-7: Preparing the FieldPilot Valve

Y

V

Y

V