TL Audio 5060 User Manual

Page 22

Advertising
background image

18



“FAT EQ”:

+2dB @ 50Hz,

-0.9dB

@

720Hz,

+1.8dB

@

10KHz.


Metering:

Illuminated VU meter displaying Channel 1 + 2 with 10dB pad,
Meter switchable to display Compressor gain reduction,
Variable intensity “Drive” LED, illuminating from +8dBu to +18dBu,
“Peak” LED monitoring whole signal chain, illuminating 6dB before clip.


Power Requirements:

Internally set to 230V 50Hz or 115V 60Hz operation,

Detachable

IEC

power

cord,

Power

consumption

30VA.


Dimensions:

19” rack mounting, 2U high,

W x H x D: 483 x 88 x 200mm (19.0” x 7.9” x 3.5”).


Shipping Weight:

6 kgs.



The above specifications are typical figures, and are subject to change without notice.