Toa S-D7802 User Manual

Page 12

Advertising
background image

12

7.3. Settings and Confirmation Procedures for Each Setting Item

7.3.1. Operation menu display's lCD screen after power-on

U 1 : 6 0 6 . 2 5 0 M H z

U 2 : 6 0 6 . 2 5 0 M H z

Confirm that the front panel Remote indicator remains unlit.

If the indicator is lit, follow the procedure below to switch the operation mode to "Local."

7.3.2. Receiver operation mode setting

Press the Right key and enter the settings menu selection hierarchy, then display the "1 RX CONTROL"

indication using the Up and Down keys.

T O P

M E N U

1

R X

C O N T R O L

Press the Right key to enter the REMOTE/LOCAL settings hierarchy, then display the "LOCAL" indication using

the Up and Down keys.

S E L E C T

R X

C T R L

[

L O C A L

]

Press the Set key to confirm the setting to "LOCAL." An asterisk ( ) is displayed, indicating that the receiver has

been set to local mode. The Remote indicator on the front panel turns off.

S E L E C T

R X

C T R L

[

L O C A L

]

For more information, see p. 27, "Remote/Local Mode Setting."

Press the Left key to navigate back up the menu structure.

Advertising