6.3. Connector Connection

Connect the mini-clamp connector supplied with the N-8000CO, to a cable using a commercially available tool

(pliers).

Step 1. Cut off two-cable ends in equal length, and insert them

securely to a cover section (transparent side) of the

mini-clamp connector.

Note

Insert the cable without stripping the cable jacket.

For cables, refer to above, "Type of Cable."

Step 2. With a pair of pliers, lightly pinch the mini-clamp cover

and, after ensuring that the cable is securely inserted,

firmly squeeze on the cover.
Note

Squeeze on the mini-clamp cover until it is correctly

locked.

Step 3. Insert the wired connector (plug) into the C/O interface unit's connector (socket) until it locks into place.

Cover (transparent side)

Cable

Mini-clamp connector

(accessory, model

232D-02S1B-DA5

manufactured by DDK Ltd.)

Rear panel

6.2. Type of Cable

The types of cables are to be determined according to the following conditions.

• UTP category 5 Straight through cables with RJ45 connector are to be used for connecting to IP network.

• The number of cables pairs laid should be determined considering the possibility of future expansion of the

system.

• Outdoor wires should be used where wiring passes through inaccessible areas such as ceilings or under

floors where the maintenance is not performed. Indoor wires may also be used, however, in case where there

is no risk of deterioration due to exposure to heat, etc.

Note

Specifications related to junction are as follows.

Mini-clamp connector (N-8000CO C/O line connection terminal)

Conductor diameter: ø 0.4 – 0.65 mm (AWG22 – 26), Solid wire

Outside diameter:

ø 1.05 mm or below